Commercial Projects

Riverview Lofts The Sagamore on East ESL Headquarters Corn Hill Landing
Members of EC4B have completed numerous Commercial Projects.  Services provided included HVAC, Electrical, Plumbing, and Fire Protection Design Services, as well as Combined Heat and Power Projects and Alternative Energy.  Below are descriptions of some of these projects:

Retail:
 
Camille's Eastview
Victor, NY
Renovation of existing lease space to accommodate requirements of the new tenant.
Cole & Parks
Victor, NY
Kitchen exhaust system installation and lighting design, 2003
MEP Engineering services for Historical Building Renovation, 2003
Court Side News & Jewels
Rochester, NY
Renovation of existing space to accommodate requirements of the new tenant.
Red Hook Stores
Brooklyn, NY
Award-Winning
New electrical service, boiler plant, absorption chillers and natural gas CHP to provide renovation five story building with new central services.
1,000 kw Induction-Parallel HVAC and DHW Recovery Cogeneration Plant and Assorption Chiller.

Community: 
 (Clubs, Centers)
Coral Creek Golf Course Placida, FL 14,000 SF golf club; heating for this facility consisted of DX Fan Coil Units.
Miromar Lakes Beach & Golf Club
Miromar Lakes, FL
21,000 SF beach club with areas including theatre room, private dining rooms, commercial catering facility, billiards room, card room, locker rooms and office space.  Heating for these areas consisted of DX Fan Coil Units.
Musket Ridge Country Club
Myersville, MD
15,000 SF additions that include a custom service kitchen and state-of-the-art banquet hall.  Design services for each space include:  custom service kitchen design, lighting, power distribution modifications, fire alarm modifications, egress lighting, all plumbing connections, heating and air conditioning of the space and split HVAC system.
Riverhll Community Center
Fort Myers, FL
18,000 SF community center with spaces including indoor pool, billiard rooms, commercial catering facility, child care, locker rooms and office space.  Heating for these areas consisted of split DX Fan Coil Units.

Office Space:
1212 Pittsford Victor Road
Pittsford, NY
Renovation and addition of Class A Office Space to a single-story building; 38,000 SF plus additionanl 20,000 SF expansion.

Lodging:
Courtyard Inn by Marriott
Rochester, NY
Fan coil HVAC system, plumbing, fire protection and electrical systems
Residence Inn by Marriott
Rochester, NY
Heat pump HVAC system, plumbing, fire protection, electrical and indoor pool
Country Inns & Suites
Rochester, NY
PTAC HVAC system, plumbing, fire protection, electrical and indoor pool
DelMonte Lodge
Rochester, NY
HVAC using roof top equipment, plumbing, fire protection, electrical and indoor pool
Marriott Airport & Thruway
Rochester, NY
Corridor and pool area sprinkler systems and lighting upgrades
Holiday Inn
Ronkonkoma, NY
Energy feasibility study and schematic design, 2001
Hudson Hotel
New York, NY
300 kW induction parallel on-site cogeneration plant with HVAC and domestic hot water recovery system
Renaissance Westchester Hotel
White Plains, NY
Energy feasibility study